-- $Id: CISCO-PAGENT-API-MIB.my,v 3.1.2.1 1997/06/18 17:58:57 kzhang Exp $
-- $Source: /nfs/repr/arkansas/cvs/Xsys/MIBS/CISCO-PAGENT-API-MIB.my,v $
--------------------------------------------------------------------
-- MIB to control Pagent API
--
-- June 1997 , Kui Zhang
--
-- Copyright (c) 1995-1998 by cisco Systems, Inc.
-- All rights reserved.
--------------------------------------------------------------------
-- $Log: CISCO-PAGENT-API-MIB.my,v $
-- Revision 3.1.2.1 1997/06/18 17:58:57 kzhang
-- Check in Pagent API MIB to Pagent_branch.
-- Branch: Pagent_branch
--
-- Revision 3.1 1997/06/18 17:24:04 kzhang
-- Add placeholder for Pagent API MIB.
----------------------------------------------------------------------
-- $Endlog$
--CISCO-PAGENT-API-MIB DEFINITIONS::=BEGINIMPORTSMODULE-IDENTITY,OBJECT-TYPE,Integer32,Gauge32FROM SNMPv2-SMI
TEXTUAL-CONVENTION,DisplayString,TruthValue
FROM SNMPv2-TC
MODULE-COMPLIANCE,OBJECT-GROUPFROM SNMPv2-CONF
--PSIM(Modif) ciscoMgmtciscoExperiment
FROM CISCO-SMI;ciscoPagentAPIMIB MODULE-IDENTITYLAST-UPDATED"9704230000Z"ORGANIZATION"Cisco Systems, Inc."CONTACT-INFO" Cisco Systems
Customer Service
Postal: 170 W Tasman Drive
San Jose, CA 95134
USA
Tel: +1 800 553-NETS
E-mail: cs-snmp@cisco.com"DESCRIPTION"MIB module for controlling Cisco Pagent API"::={ ciscoExperiment 998}ciscoPagentAPIObjects OBJECTIDENTIFIER::={ ciscoPagentAPIMIB 1}-- beginning of ciscoPagentAPIMethodTable --ciscoPagentAPIMethodTable OBJECT-TYPE--PSIM(Modif) SYNTAX SEQUENCE OF CiscoPagentAPIArgsEntrySYNTAXSEQUENCEOF CiscoPagentAPIMethodEntry
MAX-ACCESSnot-accessibleSTATUScurrentDESCRIPTION"Table to contain API names to call"::={ ciscoPagentAPIObjects 1}ciscoPagentAPIMethodEntry OBJECT-TYPESYNTAX CiscoPagentAPIMethodEntry
MAX-ACCESSnot-accessibleSTATUScurrentDESCRIPTION"An entry in the table"
INDEX{ ciscoPagentAPIMethodChannel }::={ ciscoPagentAPIMethodTable 1}
CiscoPagentAPIMethodEntry ::=SEQUENCE{
ciscoPagentAPIMethodChannel INTEGER,
ciscoPagentAPIMethodString DisplayString}ciscoPagentAPIMethodChannel OBJECT-TYPESYNTAXINTEGER(0..9)MAX-ACCESSnot-accessibleSTATUScurrentDESCRIPTION"The index of the channel of PCP"::={ ciscoPagentAPIMethodEntry 1}ciscoPagentAPIMethodString OBJECT-TYPESYNTAXDisplayStringMAX-ACCESSread-writeSTATUScurrentDESCRIPTION"The argument value"::={ ciscoPagentAPIMethodEntry 2}-- end of ciscoPagentAPIMethodTable ---- beginning of ciscoPagentAPIArgsTable --ciscoPagentAPIArgsTable OBJECT-TYPESYNTAXSEQUENCEOF CiscoPagentAPIArgsEntry
MAX-ACCESSnot-accessibleSTATUScurrentDESCRIPTION"Table to contain arguments to APIs"::={ ciscoPagentAPIObjects 2}ciscoPagentAPIArgsEntry OBJECT-TYPE
SYNTAX CiscoPagentAPIArgsEntry
MAX-ACCESSnot-accessibleSTATUScurrentDESCRIPTION"An entry in the argument table"INDEX{ ciscoPagentAPIArgsChannel, ciscoPagentAPIArgsIndex }::={ ciscoPagentAPIArgsTable 1}
CiscoPagentAPIArgsEntry ::=SEQUENCE{
ciscoPagentAPIArgsChannel INTEGER,
ciscoPagentAPIArgsIndex INTEGER,
ciscoPagentAPIArgsString DisplayString}ciscoPagentAPIArgsChannel OBJECT-TYPESYNTAXINTEGER(0..9)MAX-ACCESSnot-accessibleSTATUScurrentDESCRIPTION"The index of the channel of PCP"::={ ciscoPagentAPIArgsEntry 3}ciscoPagentAPIArgsIndex OBJECT-TYPESYNTAXINTEGER(0..30)MAX-ACCESSnot-accessibleSTATUScurrentDESCRIPTION"The index of argument, starting from 0"::={ ciscoPagentAPIArgsEntry 1}ciscoPagentAPIArgsString OBJECT-TYPESYNTAXDisplayString
MAX-ACCESSread-writeSTATUScurrentDESCRIPTION"The argument value"::={ ciscoPagentAPIArgsEntry 2}-- end of ciscoPagentArgsTable ---- beginning of ciscoPagentArgsAppendTable --ciscoPagentAPIArgsAppendTable OBJECT-TYPESYNTAXSEQUENCEOF CiscoPagentAPIArgsAppendEntry
MAX-ACCESSnot-accessibleSTATUScurrentDESCRIPTION"Table used to append strings to arguments to overcome
limitation of DisplayString length"::={ ciscoPagentAPIObjects 3}ciscoPagentAPIArgsAppendEntry OBJECT-TYPESYNTAX CiscoPagentAPIArgsAppendEntry
MAX-ACCESSnot-accessibleSTATUScurrentDESCRIPTION"An entry in the append argument table"INDEX{ ciscoPagentAPIArgsAppendChannel, ciscoPagentAPIArgsAppendIndex }::={ ciscoPagentAPIArgsAppendTable 1}
CiscoPagentAPIArgsAppendEntry ::=SEQUENCE{
ciscoPagentAPIArgsAppendChannel INTEGER,
ciscoPagentAPIArgsAppendIndex INTEGER,
ciscoPagentAPIArgsAppendString DisplayString}ciscoPagentAPIArgsAppendChannel OBJECT-TYPESYNTAXINTEGER(0..9)
MAX-ACCESSnot-accessibleSTATUScurrentDESCRIPTION"Index of the current PCP channel"::={ ciscoPagentAPIArgsAppendEntry 3}ciscoPagentAPIArgsAppendIndex OBJECT-TYPESYNTAXINTEGER(0..30)MAX-ACCESSnot-accessibleSTATUScurrentDESCRIPTION"Index of the argument to append"::={ ciscoPagentAPIArgsAppendEntry 1}ciscoPagentAPIArgsAppendString OBJECT-TYPESYNTAXDisplayStringMAX-ACCESSread-writeSTATUScurrentDESCRIPTION"Strings to append"::={ ciscoPagentAPIArgsAppendEntry 2}-- end of ciscoPagentArgsAppendTable --ciscoPagentAPIFreeChannel OBJECT-TYPESYNTAXINTEGER(0..9)MAX-ACCESSread-writeSTATUScurrentDESCRIPTION"A get on this variable returns a free channel.
A set frees up this channel."::={ ciscoPagentAPIObjects 4}-- beginning of ciscoPagentAPIResultTable --ciscoPagentAPIResultTable OBJECT-TYPESYNTAXSEQUENCEOF CiscoPagentAPIResultEntry
MAX-ACCESSnot-accessibleSTATUScurrentDESCRIPTION"A table to hold result string from API call"::={ ciscoPagentAPIObjects 9}ciscoPagentAPIResultEntry OBJECT-TYPESYNTAX CiscoPagentAPIResultEntry
MAX-ACCESSnot-accessibleSTATUScurrentDESCRIPTION"An entry in the result table."INDEX{ ciscoPagentAPIResultChannel, ciscoPagentAPIResultIndex }::={ ciscoPagentAPIResultTable 1}
CiscoPagentAPIResultEntry ::=SEQUENCE{
ciscoPagentAPIResultChannel INTEGER,
ciscoPagentAPIResultIndex INTEGER,
ciscoPagentAPIResultString DisplayString}ciscoPagentAPIResultChannel OBJECT-TYPESYNTAXINTEGER(0..9)MAX-ACCESSnot-accessibleSTATUScurrentDESCRIPTION"Index of the channel for PCP"::={ ciscoPagentAPIResultEntry 3}ciscoPagentAPIResultIndex OBJECT-TYPE
SYNTAXINTEGER(0..255)MAX-ACCESSnot-accessibleSTATUScurrentDESCRIPTION"Index of the result table."::={ ciscoPagentAPIResultEntry 1}ciscoPagentAPIResultString OBJECT-TYPESYNTAXDisplayStringMAX-ACCESSread-writeSTATUScurrentDESCRIPTION"Variable to hold the result string, in case the string
is long, it is broken into DisplayString of 255 chars and
stored in the table, one DisplayString per row."::={ ciscoPagentAPIResultEntry 2}-- end of ciscoPagentAPIResultTable --ciscoPagentAPINotifications OBJECTIDENTIFIER::={ ciscoPagentAPIMIB 2}-- (no notifications are currently defined)-- conformance informationciscoPagentAPIConformance OBJECTIDENTIFIER::={ ciscoPagentAPIMIB 3}ciscoPagentAPICompliances OBJECTIDENTIFIER::={ ciscoPagentAPIConformance 1}ciscoPagentAPIGroups OBJECTIDENTIFIER::={ ciscoPagentAPIConformance 2}-- compliance statementsciscoPagentAPICompliance MODULE-COMPLIANCESTATUScurrent
DESCRIPTION"The compliance statement for entities which implement
the Cisco Pagent API MIB"MODULE-- this module
--PSIM(Modif) MANDATORY-GROUPS { ciscoPagentAPIGroup }MANDATORY-GROUPS{ ciscoPagentGroup }::={ ciscoPagentAPICompliances 1}-- units of conformanceciscoPagentGroup OBJECT-GROUPOBJECTS{
ciscoPagentAPIMethodTable,
ciscoPagentAPIArgsTable,
ciscoPagentAPIFreeChannel,
ciscoPagentAPIArgsAppendTable,
ciscoPagentAPIResultTable
}STATUScurrentDESCRIPTION"TBD"::={ ciscoPagentAPIGroups 1}END